We are a big printing company in Shenzhen China . We offer all book publications, hardcover book printing, papercover book printing, hardcover notebook, sprial book printing, saddle stiching book printing, booklet printing,packaging box, calendars, all kinds of PVC, product brochures, notes, Children's book, stickers, all kinds of special paper color printing products, game cardand so on.
For more information please visit
http://www.joyful-printing.com. ENG only
http://www.joyful-printing.net
http://www.joyful-printing.org
email: info@joyful-printing.net
1.SYSTEM ERROR #1
[Fault Description]: The problem of filming
[Formation reasons]: 1. The motor of the film is loose, not accessible; 2. The belt is loose; 3. The motor is bad; 4. The main control board is broken.
[Solution]: 1. Turn on the machine to see if the motor is rotating; 2. If the motor does not turn, check if the motor connection voltage is normal (+24V); 3. If the motor rotates normally, tighten the belt. Report 1# error 80% is due to the loose belt, or a new belt.
2.SYSTEM ERROR #2
[Fault Description]: Laser SOL (line sync) signal is not detected
[Formation reasons]: 1. The laser head is bad, there is no laser signal; 2. The scanning motor does not turn; 3. The SOL sensor position is not suitable; 4. The laser light intensity is weak.
[Solution]: 1. Check the connection on the laser control board, you can use the multimeter to measure one by one; 2. Check whether there is laser at boot, you can put a blank sheet of paper in the position of the laser sensor, boot for about 6-8 seconds There is a red light flashing over; 3. Check if the scanning motor rotates; 4. Check if the SOL sensor is loose and clean the mirror surface; 5. Eliminate the above reasons, the panel displays “SYSTEM ERROR #2/PRESS”. PREV TO RESTAR", after rotating the R33 on the laser control panel counterclockwise about 45 °, press the PREV button to restart until the boot is normal; 6. Replace the main control board.
3.SYSTEM ERROR #3
[Fault Description]: NO ACTIVE VIDEO
[Formation reasons]: 1. The jumper J1 on AD27354 is not installed; 2. There is a problem with the main control board.
[Solution]: 1. Check if jumper J1 is installed; 2. Replace the main control board.
4.SYSTEM ERROR #4
[Fault Description]: The cutter cannot work
[Formation reasons]: 1. Card; 2. The cutter does not work; 3. The fixed cutter pulley is loose; 4. The Sensor has a problem.
[Solution]: 1. Check whether the card, general #4 error is caused by this; 2. Check the cutter motor, Sensor connection; 3. Check if the cutter is loose
5.SYSTEM ERROR #5
[Fault Description]: Lazy Loop Failed ring failure
[Formation reasons]: 1. The ring encoder is invalid; 2. The main control board has a problem.
[Solution]: 1. Check the cable connection and power supply; 2. Replace the ring encoder; 3. Replace the main control board.
6.SYSTEM ERROR #7
[Fault Description]: The first/tail punching device gives an error.
[Formation reasons]: 1. The connection is loose; 2. The first/tail hole is broken; 3. The main control board has a problem; 4. The reset sensor is invalid or improperly adjusted.
[Solution]: 1. Check the connection and power supply; 2. The puncher needs lubrication; 3. Replace the punching device; 4. Replace the main control board.
7.SYSTEM ERROR #8
[Fault Description]: PINCH is not reset
[Formation reasons]: 1. The connection is loose; 2. The PINCH MORTOR is bad; 3. The PINCH sensor and the disc are not in the proper position.
[Solution]: 1. Check the connection; 2. Check if there is 15V voltage on the PINCH MORTOR; 3. Adjust the position of the Sensor and the disc.
8.SYSTEM ERROR #9
[Fault Description]: SPINNER CONFIDEUCE TEST FAILURE scan test failed
[Formation reasons]: 1. Connection loose; 2. Insufficient voltage (scan motor voltage should be +24V); 3. Motor control board is bad; 4. Scan motor is bad.
[Solution]: 1. Check the main control board, scan motor control board, scan motor connection; 2. Check whether the 24V voltage is normal; 3. Check the scanning control board fixing screws to check whether the control board has short circuit; 4. Replace Motor control board; 5. Replace the scanning motor.